beautypg.com

Element types – HP StorageWorks 2500 Disk System User Manual

Page 43

background image

Table 6 Element types

Et Code

Component

0.1.

Disk drive

0.2.

Power supply

0.3.

Blower

0.4.

Temperature sensor

0.6

Audible alarm

1

0.7.

EMU

0.F.

Transceivers

1.0.

Language

1

1.1.

Communication port

1

1.2.

Voltage sensor

1.3

Current sensor

8.0

DS2500 enclosure

1

8.2.

DS2500 backplane

8.7.

I/O module

1

Does not generate a condition report. However, for any error, you should record the error code and implement the

recommended corrective action.

Viewing an error condition report

IMPORTANT:

Always write down the error condition report contents, including the decimal points. You can tell which

digits are displayed by the position of the decimal points.

To view the error condition report:

1.

Tap the bottom push button until Er appears in the alphanumeric display, if necessary.

2.

Press and hold the top push button until the display changes to the first two digits of the error

condition report. (For example, 0.3.)

3.

Tap the top push button to display the next two digits of the error condition report. (For example, 01.)

4.

Tap the top push button again to display the last two digits of the error condition report. (For

example, 03)
If you tap the top push button again, the current error condition will cycle through the alphanumeric

display.

5.

If the top push button orange LED is lit after viewing the error condition report, another error code is

active in the queue. Repeat

Step 2

through

Step 4

to view the error condition report.

6.

Tap the bottom push button to return to the Er display.

See

Appendix C

for a description of the EMU-generated error condition reports and corrective actions.

2500 Disk System user guide

43