Power specifications, Ds2500 ac input line voltages – HP StorageWorks 2500 Disk System User Manual

Page 64

background image

When shipping, or placing this product in short term storage, HP recommends maintaining the

environmental conditions listed in

Table 15

.

Table 15 Environmental shipping or short-term storage specifications

Ambient temperature: -40°C to +66°C (-40°F to +151°F)
Relative humidity: 10% to 80% (noncondensing)
Altitude: 15,240 m (50,000 ft)

Power specifications

The input voltage to the DS2500 power supplies is a function of the country-specific input voltage to

storage system rack power distribution units (PDUs).

Table 16

defines the AC input power available to

the DS2500 power supplies.

CAUTION:

The AC power distribution within a rack ensures a balanced load to each PDA and reduces the

possibility of an overload condition. Changing the cabling to or from a PDM could cause an overload

condition.

Table 16 DS2500 AC input line voltages

Specification

Minimal

Nominal

Maximum

60 Hz service

AC line frequency

57 Hz

60 Hz

63 Hz

AC line voltage—Japan

180 VAC

202 VAC

220 VAC

AC line voltage—North America

180 VAC

208 VAC

220 VAC

AC line voltage—Europe

208 VAC

240 VAC

254 VAC

50 Hz service
AC line frequency

47 Hz

50 Hz

53 Hz

AC line voltage—Japan

180 VAC

202 VAC

220 VAC

AC line voltage—North America

190 VAC

220 VAC

235 VAC

AC line voltage—North America

200 VAC

230 VAC

244 VAC

AC Line Voltage—Europe

208 VAC

240 VAC

254 VAC

64

Specifications