4 Using the EMU

This chapter contains the following topics:

Alphanumeric display

, page 39

Display groups

, page 39

Alphanumeric display

The EMU stores information about the status of the DS2500. You can use the EMU alphanumeric display

to view the status information. The push buttons below the display provide a way to select which

data is displayed and to enter data.
The alphanumeric display shows multiple levels of information. The top level shows a display group

(see

Table 4

). Each display group has supporting data in sublevels.

The bottom push button allows you to sequentially view and select the display groups.

The top push button allows you to sequentially view the levels within a display group.

The push buttons double as status indicators:

The top push button lights when an error condition exists.
• For a single error, the push button stays lit until the error condition report is viewed.
• For multiple errors, the push button remains lit until the last error condition report is viewed.

The bottom push button lights when the audible alarm is muted or disabled.

Display groups

By default, the enclosure ID (En) appears in the alphanumeric display. When you press and release the

bottom push button, the display cycles among the display groups listed in

Table 4

.

A flashing alphanumeric display indicates that you can edit the contents of a display group.

Table 4 EMU display groups

Display group

Display

Description

Encoding

En

Used to encode or assign the enclosure ID.

Loop ID

Li

Identifies the enclosure loop ID.

Reporting Group

rG

Not used in a JBOD environment.

Audible alarm

Au

Allows you to control the audible alarm or horn. The sublevel

displays are audible alarm enabled (On) or audible alarm

disabled (OF).

Firmware revision

Fr

Displays the EMU firmware version.

Error condition

Er

Indicates an error condition.

Encoding the enclosure ID (En)

All enclosures must have a hard address to function properly with HP-UX operating software. You must

assign a unique enclosure ID and corresponding loop ID to each DS2500. There are nine allowable

enclosure ID/loop ID pairs. See

Table 5

for enclosure IDs and the corresponding loop ID numbers.

2500 Disk System user guide