Power supply and blower assembly, Features, Power supply and blower status indicator – HP StorageWorks 2500 Disk System User Manual

Page 21: Power supply and blower assembly components, Power supplies and blowers

background image

Power supply and blower assembly

Figure 6

shows the power supply and blower assembly components.

3

1

4

5

2

5

6

25206a

Figure 6 Power supply and blower assembly components

1. Power supply assembly

4. Module latch

2. Status LED

5. Blower tabs (2)

3. AC input connector with bail lock

6. Blower

Features

Only one operational power supply and one operational blower are required to keep the enclosure fully

functional. However, in the event of a component failure, HP strongly recommends that a replacement is

installed as soon as possible.

NOTE:

When a power supply fails, the associated blower is disabled.

The power supply circuitry monitors input voltage, current, and temperature. If it detects an unacceptable

level of any of these elements, the status indicator turns off and an error is reported to the EMU.
The EMU uses the temperature sensor signal to adjust the speed of the blowers. If one blower fails or

spins at a reduced speed, the speed of the other blower increases to provide adequate air flow.

Power supply and blower status indicator

A green LED on the blower (

Figure 6

-2) indicates the operational status of the power supply and the

blower. If either component fails, the LED turns off and an error alarm sounds. The failing component

should be replaced as soon as possible.

2500 Disk System user guide