Uplinkport – HP Virtual Connect 8Gb 24-port Fibre Channel Module for c-Class BladeSystem User Manual
Page 97

Command line 97
Item
Description
SecondaryServerKey
(optional)
The plain-text string used to encrypt user details exchanged with the secondary
TACACS server. It must match the server key configured for this VC on the
secondary server. TACACS authentication will not work if the server key is blank
or null.
SecondaryTimeout
(optional)
The timeout value in seconds for TACACS communication with the secondary
server
LoggingEnabled
(optional)
Enables or disables command logging on the TACACS+ server. Valid values
include "true" and "false".
Examples
->set tacacs -test Enabled=true ServerAddress=192.168.0.27
Tests the TACACS+ configuration changes without applying them
->set tacacs Enabled=true ServerAddress=192.168.0.124
ServerKey=test123 SecondaryServerAddress=tacserver.hp.com
SecondaryServerKey=test456
Enables TACACS+ authentication for users
->set tacacs LoggingEnabled=true
Enables TACACS server logging
Item
Description
show tacacs
Display the Virtual Connect TACACS+ authentication settings.
Syntax
show tacacs
Example
->show tacacs
Displays TACACS+ information
uplinkport
Manage interconnect module uplink ports.
Supported actions: add, help, remove, set, show
Item
Description
add uplinkport
Add a new uplink port to an existing network or a shared uplink port set.
Syntax
add uplinkport
UplinkSet=
[Speed=
[Role=
Parameter
PortID (required) The ID of an uplink port to add. The ID is a combination of the enclosure name,
interconnect bay, and port number in a single descriptor. The format of the port ID is
Properties
Network
(required)
The name of an existing network to which the port is added if the shared uplink set
name is not specified
UplinkSet
(required)
The name of an existing shared uplink set to which the port is added if the network
name is not specified
Speed (optional) Specifies the port speed for the port (optional). Valid values include "Auto", "10Mb",
"100Mb", "1Gb", "10Gb", and "Disabled". If not specified, the default port speed is
"Auto". If no connector is present on the uplink port, only "Auto" and "Disabled" can
be configured as the speed. Speed restrictions apply.
- 1.10GB Virtual Connect Ethernet Module for c-Class BladeSystem Virtual Connect 8Gb 20-port Fibre Channel Module for c-Class BladeSystem Virtual Connect 1.10Gb-F Ethernet Module for c-Class BladeSystem Virtual Connect Flex-10 10Gb Ethernet Module for c-Class BladeSystem 4GB Virtual Connect Fibre Channel Module for c-Class BladeSystem Virtual Connect FlexFabric 10Gb24-port Module for c-Class BladeSystem Virtual Connect 4Gb Fibre Channel Module for c-Class BladeSystem