Fcoe-connection – HP Virtual Connect 8Gb 24-port Fibre Channel Module for c-Class BladeSystem User Manual
Page 39

Command line 39
Item
Description
->show fc-connection Profile1:*
Displays all FC SAN connections of a profile named Profile1
->show fc-connection Profile1:1
Displays a specific FC SAN connection of a profile named Profile1
fcoe-connection
Manage FCoE connections.
Supported actions: add, help, remove, set, show
Item
Description
add fcoe-connection
Add a new FCoE connection to an existing server profile.
For more information, see "General requirements for adding FC or FCoE
)."
Syntax
add fcoe-connection
[SpeedType=<1Gb|2Gb|4Gb|8Gb|Custom|Disabled>]
[CustomSpeed=<100Mb-10Gb>]
[WWNAddressType=
[PortWWN=
[MACAddressType=
[EthernetMac=
Parameter
ProfileName (required) The name of an existing profile to which the new connection is added
Properties
Fabric (optional)
The name of an existing fabric created on an FCoE module to associate with the
connection. If the fabric name is not specified, the connection is marked as
“Unassigned” and associated with a specific bay.
SpeedType (optional)
The requested operation speed for the server port. Valid values include "1Gb",
"2Gb", "4Gb", "8Gb", "Custom", and "Disabled". The default value is "4Gb".
If the SpeedType is "Custom", you can configure any speed from 100Mb to
10Gb in 100Mb increments.
CustomSpeed (required
if SpeedType is Custom)
The user-defined speed for the server port. Valid values include 100Mb to
10Gb configured in 100Mb increments.
WWNAddressType
(optional)
The source of WWN address assignments to be used during the creation of the
new connection. If not specified, the default is the domain default. If
"User-Defined" is specified, both a Port WWN and Node WWN must also be
specified. Valid values include "Factory-Default" and "User-Defined".
PortWWN (required if
WWNAddressType is
User-Defined)
The user-defined Port WWN address to use for the connection. The PortWWN
must be an unused WWN address.
NodeWWN (required if
WWNAddressType is
User-Defined)
The user-defined Node WWN address to use for the connection. The
NodeWWN must be an unused WWN address.
MACAddressType
(optional)
The source of MAC address assignments to be used during the creation of the
new connection. If not specified, the default is the domain default. If
"User-Defined" is specified, EthernetMAC must also be specified. Valid values
include "Factory-Default" and "User-Defined".
EthernetMAC (required
if MACAddressType is
User-Defined)
The user-defined Ethernet MAC address to use for the connection
Examples
- 1.10GB Virtual Connect Ethernet Module for c-Class BladeSystem Virtual Connect 8Gb 20-port Fibre Channel Module for c-Class BladeSystem Virtual Connect 1.10Gb-F Ethernet Module for c-Class BladeSystem Virtual Connect Flex-10 10Gb Ethernet Module for c-Class BladeSystem 4GB Virtual Connect Fibre Channel Module for c-Class BladeSystem Virtual Connect FlexFabric 10Gb24-port Module for c-Class BladeSystem Virtual Connect 4Gb Fibre Channel Module for c-Class BladeSystem