Ldap – HP Virtual Connect 8Gb 24-port Fibre Channel Module for c-Class BladeSystem User Manual
Page 50

Command line 50
Item
Description
Properties
Network (optional)
The name of an existing network to associate with the connection. If the network
name is not specified or is unassigned, it can be assigned later.
SpeedType (optional)
The requested operational speed for the server port. Valid values include
"Auto", "Preferred", and "Custom". The default value is "Preferred".
If the speed type is "Auto", the maximum port speed is allocated, constrained by
the maximum configured speed for the network.
If the speed type is "Preferred", the speed of the network is the same as the
preferred speed of the network to which the connection is associated. If no
preferred speed is configured for a network, it defaults to "Auto".
If the speed type is "Custom", you can configure a speed (using the Speed
property) from 100Mb to the MAX configured speed for the network in 100Mb
increments.
Speed (required if the
Speedtype is Custom)
The user-defined speed for the server port. Valid values include from 100Mb to
the MAX configured speed for the network in 100Mb increments.
Examples
->set iscsi-connection MyNewProfile:1 Network=SomeNetwork
Changes the network to a different one
->set iscsi-connection MyNewProfile:1 Network=""
Unassigns the network from the connection
->set iscsi-connection MyProfile:1 Network=MyNetwork
SpeedType=Preferred
Modifies the speed to Preferred
->set iscsi-connection MyProfile:1 SpeedType=Custom
Speed=2000
Modifies the iSCSI connection and sets the speed to 2Gb
Item
Description
show iscsi-connection Display the iSCSI connections associated with the server profiles.
Syntax
show iscsi-connection [
Parameter
ConnectionID
(optional)
The ID of an existing iSCSI connection. The ID format is
Use
display all iSCSI connections in the domain.
Examples
->show iscsi-connection
Displays all iSCSI connections in the domain
->show iscsi-connection Profile1:*
Displays all iSCSI connections of a profile named Profile1
->show iscsi-connection Profile1:1
Displays a specific iSCSI connection of a profile named Profile1
ldap
Manage Virtual Connect directory server authentication settings.
- 1.10GB Virtual Connect Ethernet Module for c-Class BladeSystem Virtual Connect 8Gb 20-port Fibre Channel Module for c-Class BladeSystem Virtual Connect 1.10Gb-F Ethernet Module for c-Class BladeSystem Virtual Connect Flex-10 10Gb Ethernet Module for c-Class BladeSystem 4GB Virtual Connect Fibre Channel Module for c-Class BladeSystem Virtual Connect FlexFabric 10Gb24-port Module for c-Class BladeSystem Virtual Connect 4Gb Fibre Channel Module for c-Class BladeSystem