HP Virtual Connect 8Gb 24-port Fibre Channel Module for c-Class BladeSystem User Manual
Page 82

Command line 82
Item
Description
Examples
->add server-port-map MyProfile:1 Network1 VLanID=100
Adds a new server port to dedicated network mapping
->add server-port-map MyProfile:2 RedNetwork
Uplinkset=MyUplinkSet1
Adds a new server port to shared network mapping
->add server-port-map MyProfile:3 GreenNetwork
Uplinkset=MyUplinkset1 UnTagged=true
Adds a new server port to shared network mapping and enables untagged packet
handling
Item
Description
remove
server-port-map
Remove a server port network mapping.
Syntax
remove server-port-map
Parameters
ConnectionID
(required)
The ID of an existing Ethernet connection associated with a profile and a server
port. The format of the ConnectionID is
to remove all server-port-map configurations from the domain.
Network (optional) The name of an Ethernet network on which the mapping exists
Examples
->remove server-port-map MyProfile:1 RedNetwork
Removes a server port network mapping
->remove server-port-map MyProfile:1 *
Removes all server port network mappings from a profile
->remove server-port-map *
Removes all server port mappings in the domain
Item
Description
set server-port-map Modify an existing server port network mapping. This command cannot be used if
the network is associated with a shared uplink set.
Syntax
set server-port-map
[VLanID=
Parameters
ConnectionID
(required)
The ID of an existing Ethernet connection associated with a profile and a server
port. The format of the ConnectionID is
Network (required) The name of a valid Ethernet network on which the mapping exists
Properties
VLanID (optional)
The new VLAN ID to be used for server port network mapping. Valid values include
1 to 4094.
Untagged (optional) Enables or disables the network to handle untagged packets. Only one network in
an Ethernet network connection can handle untagged packets. The default value is
"false". If a shared uplink set is used, the untagged network is the same as the native
network, if present, but any network can also be configured to handle untagged
packets. When changing a network untagged option from "true" to "false", you
must specify a VLanID if the global option SharedServerVLanId is set to "false".
Examples
->set server-port-map MyProfile:1 Network1 VLanId=100
Modifies the VLAN ID of an existing server port network mapping
- 1.10GB Virtual Connect Ethernet Module for c-Class BladeSystem Virtual Connect 8Gb 20-port Fibre Channel Module for c-Class BladeSystem Virtual Connect 1.10Gb-F Ethernet Module for c-Class BladeSystem Virtual Connect Flex-10 10Gb Ethernet Module for c-Class BladeSystem 4GB Virtual Connect Fibre Channel Module for c-Class BladeSystem Virtual Connect FlexFabric 10Gb24-port Module for c-Class BladeSystem Virtual Connect 4Gb Fibre Channel Module for c-Class BladeSystem