Command line 29
Item
Description
AddressType (optional)
The source of MAC address assignments to be used during the creation of
the new connection. If not specified, the default is the domain default. If
"User-Defined" is specified, both an Ethernet MAC Address and iSCSI
MAC Address must also be specified. Valid values include
"Factory-Default" and "User-Defined".
EthernetMAC (required if
AddressType is
User-Defined)
The user-defined Ethernet MAC address to use for the connection. This
property is required if the AddressType specified is "User-Defined".
iScsiMAC (required if
AddressType is
User-Defined)
The user-defined iSCSI MAC address to use for the connection. This
property is required if the AddressType specified is "User-Defined".
SpeedType (optional)
The requested operational speed for the server port. Valid values include
"Auto", "Preferred", and "Custom". The default value is "Preferred".
If the speed type is "Auto", the maximum port speed is determined by the
maximum configured speed for the network.
If the speed type is "Preferred", the speed of the network is the same as the
preferred speed of the network to which the connection is associated. If no
preferred speed is configured for a network, it defaults to "Auto".
If the speed type is "Custom", you can configure a speed from 100Mb to
MAX configured speed for the network in 100Mb increments.
Speed (required if the
SpeedType is Custom)
The user-defined speed for the server port. Valid values include 100Mb to
MAX configured speed for the network in 100Mb increments.
Examples
->add enet-connection MyNewProfile
Network=SomeNetwork
Adds a new Ethernet network connection to a profile
->add enet-connection MyNewProfile
Network=SomeNetwork2 PXE=enabled
Adds a new Ethernet network connection and enables PXE
->add enet-connection MyNewProfile
Adds a new Ethernet network connection and leaves the network
unassigned
->add enet-connection MyNewProfile
AddressType=Factory-Default
Adds a new Ethernet network connection and uses factory default
addresses
->add enet-connection MyNewProfile
AddressType=User-Defined
EthernetMAC=00-17-A4-77-00-00
iScsiMAC=00-17-A4-77-00-01
Adds a new Ethernet network connection and provides user-defined MAC
addresses
->add enet-connection MyProfile Network=MyNetwork
SpeedType=Preferred
Adds a new Ethernet network connection and sets the speed to
"Preferred"
->add enet-connection MyProfile Network=MyNetwork
SpeedType=Custom Speed=2000
Adds a new Ethernet network connection and sets the speed to 2Gb
Item
Description
remove enet-connection
Remove the last Ethernet network connection from an existing server
profile.
Syntax
remove enet-connection
- 1.10GB Virtual Connect Ethernet Module for c-Class BladeSystem Virtual Connect 8Gb 20-port Fibre Channel Module for c-Class BladeSystem Virtual Connect 1.10Gb-F Ethernet Module for c-Class BladeSystem Virtual Connect Flex-10 10Gb Ethernet Module for c-Class BladeSystem 4GB Virtual Connect Fibre Channel Module for c-Class BladeSystem Virtual Connect FlexFabric 10Gb24-port Module for c-Class BladeSystem Virtual Connect 4Gb Fibre Channel Module for c-Class BladeSystem