background image

Command line 45

Item

Description

interconnect bay number 5

->show interconnect enc0:*

Displays interconnect modules in all bays of a specific enclosure

->show interconnect enc0:3

Displays detailed information on a specific interconnect module in interconnect

bay 3 of the primary enclosure

interconnect-mac-table

Display interconnect module MAC table information.
Supported actions: help, show

Item

Description

show interconnect-

mac-table

Display interconnect module MAC table information for the specified module.

Syntax

show interconnect-mac-table

Parameter

ModuleID (required)

The ID of the module for which to display the MAC table. The ID is in the format

of :.

Example

->show interconnect-mac-table enc0:1

Displays the module MAC table for the module in bay 1 of enclosure enc0

iscsi-boot-param

Manage iSCSI boot parameters within a domain.
Supported actions: help, remove, set, show

Item

Description

remove

iscsi-boot-param

Remove all iSCSI boot parameters configured on the specified iSCSI

connection.

Syntax

remove iscsi-boot-param

Parameter

ConnectionID

(required)

The ID of an existing iSCSI connection. The ID format is . To
retrieve the port number of the iSCSI connection, use the show profile

command.

Example

->remove iscsi-boot-param MyProfile1:1

Removes boot parameters configured on connection 1 of MyProfile1

Item

Description

set iscsi-boot-param

Configure the basic iSCSI boot parameters on the specified iSCSI connection.

Syntax

set iscsi-boot-param [-maskSecret]

[-maskMutualSecret]

[BootOrder=]

[LUN=] [InitiatorName=

name>] [InitiatorIP=] [Mask=]

[Gateway=] [VlanID=]