Tacacs – HP Virtual Connect 8Gb 24-port Fibre Channel Module for c-Class BladeSystem User Manual
Page 96

Command line 96
Item
Description
Pause
The number of records to be viewed before prompting for a key press. Valid values
include numbers between 1 and 40.
Examples
->show systemlog
Displays the entire system log
->show systemlog -pause=8
Displays the system log, eight records at a time
->show systemlog -first=12
Displays the first twelve records from the system log
->show systemlog -last=8
Displays the last eight records from the system log
->show systemlog -last=20 -pause=6
Displays the last twenty records from the system log, six records at a time
To add a remote target, see "add log-target (on page
)."
tacacs
Manage TACACS+ authentication settings.
Supported actions: help, set, show
Item
Description
set tacacs
Modify and test the Virtual Connect TACACS+ authentication settings.
Syntax
set tacacs [-test] [Enabled=
[ServerAddress=
[ServerKey=
[SecondaryServerAddress=
[SecondaryPort=
[SecondaryTimeout=
[LoggingEnabled=
Option
Test (optional)
Tests the TACACS+ configuration without applying changes
Properties
Enabled (optional)
Enables or disables TACACS+ authentication. Valid values include "true" and
"false".
ServerAddress
(optional)
The IP address or the DNS name of the primary TACACS+ server used for
authentication
Port (optional)
The server TCP port number. Valid values include a valid port number between 1
and 65535. The default port number is 49.
ServerKey (optional) The plain-text string used to encrypt user details exchanged with the primary
TACACS server. It must match the server key configured for this VC on the
primary server. TACACS authentication will not work if the server key is blank or
null.
Timeout (optional)
The time in seconds by which a server response must be received before a new
request is made. The valid range of values is from 1 to 600 seconds. The default
timeout is 10 seconds.
SecondaryServer
Address (optional)
The IP address or host name of the secondary TACACS server used for
authentication
SecondaryPort
(optional)
The TCP port to use for TACACS communication. Valid values include a valid port
number between 1 and 65535. The default TCP port number is 49.
- 1.10GB Virtual Connect Ethernet Module for c-Class BladeSystem Virtual Connect 8Gb 20-port Fibre Channel Module for c-Class BladeSystem Virtual Connect 1.10Gb-F Ethernet Module for c-Class BladeSystem Virtual Connect Flex-10 10Gb Ethernet Module for c-Class BladeSystem 4GB Virtual Connect Fibre Channel Module for c-Class BladeSystem Virtual Connect FlexFabric 10Gb24-port Module for c-Class BladeSystem Virtual Connect 4Gb Fibre Channel Module for c-Class BladeSystem