Critical event messages – HP Integrity NonStop J-Series User Manual
Page 224
Error Messages
HP NonStop AutoTMF Software User’s Guide—429952-017
D-4
Critical Event Messages
150
Cause. A message from AutoTMF has been generated.
Effect. The nature of the problem is described in the message.
Recovery. Corrective action depends on the message.
Critical Event Messages
402
Cause. The monitor process has been intentionally abended to produce a saveabend
file for problem diagnosis.
Effect. The primary monitor process abends. The backup process takes over and
continues processing.
Recovery. Send the saveabend file to product support.
403
Cause. An operation was attempted, but no license for that service has been installed.
Effect. The operation is rejected.
Recovery. Obtain and install the necessary license.
406
Cause. The dialogue between the AutoTMF runtime and the monitor failed.
Effect. The program abends.
Recovery. Check for other messages in the EMS log. One probable cause is that the
runtime and the monitor are different versions. Correct the problem and restart the
program.
AutoTMF message
Monitor intentionally abended
Invalid license
Communication error between the runtime and the monitor