HP Integrity NonStop J-Series User Manual
Page 108

NonStop AutoTMF Commands
HP NonStop AutoTMF Software User’s Guide—429952-017
6-32
ALTER ATMFPROGRAMS
The AutoTMF runtime generates periodic EMS messages to alert the
operator of long running transactions, which are usually caused by a
program holding locks and preventing AutoTMF from committing an automatic
transaction.
The EMS message displays the transaction identifier of the long running
transaction, the name of the process holding the locks and the time remaining
before the transaction reaches the AutoCommit limit.
value: is n [ SEC[ONDS] | MIN[UTES] ], between 5 and 30 minutes. A
value entered as n SEConds is rounded up to minutes.
NEVER: suppresses the display of long transaction warning messages.
DEFAULT: resets the interval to 5 minutes.
NO: is equivalent to DEFAULT.
Note. Removing an option specifying NO is different from setting it to the default value. The
default value setting overrides the global (or local) value. Removing the option adopts the
setting from the global (or local) setting.