NonStop AutoTMF Commands

HP NonStop AutoTMF Software User’s Guide429952-017

6-42

ALTER GLOBAL

DEFAULT: sets the interval to 5 minutes.

DYNAMICTRACE { ON | OFF }

enables or disables dynamic tracing.

When dynamic tracing is enabled, a prepared program periodically checks a
signal file to see if tracing has been requested for that process. The checks are
performed when the process calls READUPDATE on $RECEIVE, all forms of
calls to OPEN, KEYPOSITION, WRITEREAD, DELAY and to
SEVERCLASS_SEND_.

If tracing has been requested, the process starts to write the captured
information to the configured trace file until tracing is turned off. Note that the
same signal file is checked for a request to stop tracing.

Note that to take effect, DYNAMICTRACE must be enabled prior to starting the
application programs.

The default is DYNAMICTRACE ON.

EMSCOLLECTOR collector-process

logs AutoTMF events to an alternate collector process. EMS events are
internal and generally related to configuration problems or process failures.

collector-process must be an existing EMS collector, having a device type 1
and subtype 0; otherwise, the command is ignored.

The default is $0.

If omitted, the collector process is set to the default collector $0.

SECURETRACE ON | OFF

controls tracing of processes by users other than the owner of the process.

The default is ON, which restricts tracing privileges to the owner of the
process.

[SWAP]KMSF { ON | OFF }

enables or disables KMSF swap file allocation.

If an error occurs on the swap file allocation, the runtime reverts to the normal
swap file allocation, either using the SWAPVOLn global specification or the
default swap file.

The default is OFF.

SWAPVOL[0] local-disk-volume
SWAPVOL1 local-disk-volume
SWAPVOL2 local-disk-volume
SWAPVOL3 local-disk-volume