Alter monitor, Also be changed using the, Command – HP Integrity NonStop J-Series User Manual
Page 120
![background image](/manuals/397618/120/background.png)
NonStop AutoTMF Commands
HP NonStop AutoTMF Software User’s Guide—429952-017
6-44
ALTER MONITOR
BACKUP 0-to-15
cpu number of the backup monitor process.
HOMETERM file-name
the home terminal for the monitor process.
If NONE or omitted, the home terminal is set to the default EMS collector. The
default EMS collector is $0, or the EMS collector configured by setting the
global parameter EMSCOLLECTOR.
.MONITOR process-name
the AutoTMF monitor process to associate with the MapDB subvolume. The
name must be 5 characters long including the $. The default is $ZESC.
PRIMARY 0-to-15
cpu of the primary monitor process.
PRIORITY 1-to-199
priority of the monitor process.
ALTER MONITOR
Alters attributes of the monitor process. Changes take effect when the monitor process
is restarted.
These attributes can also be changed using the
process-name
Note.
Internally, if the default collector is $0, the default hometerm of the
monitor is $ZHOME, as displayed by the TACL command STATUS $process-
name, because $0 cannot be specified as the hometerm of a process when the
process is launched. Functionally however, the home terminal for the monitor
process is always the default EMS collector, as shown in the output of
.
ALTER MONITOR [process-name] { , option };
option is
{ BACKUP 0-to-15
}
{
}
{ HOMETERM [ file-name | NONE ]}
{
}
{ PRIMARY 0-to-15
}
{
}
{ PRIORITY 1-to-199
}