HP Integrity NonStop J-Series User Manual
Page 223
Error Messages
HP NonStop AutoTMF Software User’s Guide—429952-017
D-3
Informational Messages
107
Cause. The monitor process has displayed status information.
Effect. Status information is placed in the EMS log.
Recovery. Informational message only; no corrective action is needed.
141
Cause. A long-running automatic transaction has been detected. AutoTMF usually
commits transactions after a short interval, but may not be able to do so if applications
have long-lasting database locks. AutoTMF reports long-running transactions after five
minutes.
Effect. The automatic transaction is not committed. AutoTMF will continue to attempt
committing the transaction. Eventually, if the transaction is not committed by the time
the TMF AutoAbort timeout is reached, a unilateral abort will cause the program to fail
and the transaction to be backed out.
Recovery. Informational message only. Determine the cause and effect of the long-
running transaction. Ensure that the long-running transaction is not subject to an
AutoAbort; otherwise, you may need to change the TMF AutoAbort timer.
142
Cause. Configuration could not be accessed from the MapDB tables.
Effect. Configuration information is not available to the monitor; requested services
will not be performed.
Recovery. Correct the table access problem and issue the MONITOR REFRESH
NOW command.
143
Cause. Configuration information in the MapDB tables is inconsistent.
Effect. The configuration information is not available on request to the monitor.
Recovery. Correct the configuration information.
Monitor status info
Overdue commit on automatic transaction.
MAPDB access error
MAPDB inconsistent