NonStop AutoTMF Commands

HP NonStop AutoTMF Software User’s Guide429952-017

6-43

ALTER LOCAL

the extended-memory swap file volumes for the AutoTMF runtime library
private segment.

If local-disk-volume is omitted, the SWAPVOLn setting is deleted.

When a program is launched an extended memory segment and its disk swap
files are allocated. The specified volumes are used randomly: all are tried until
one succeeds. If the volumes all fail, the process default swap volume is also
tried.

ALTER LOCAL

Sets or changes a local parameter value. Local parameters are the same as
global parameters and have the same purpose, but they are in effect for the
current Monitor (MapDB) only. Local parameter values are stored in the MapDB
table REGISTRY. Setting a local parameter value overrides the global (default)
value.

See

ALTER GLOBAL

above for a description of parameter-and-value.

ALTER MAPDB

Alters MapDB attributes; most of these attributes pertain to the monitor process, not
the mapping database. Changes take effect when the monitor process is restarted.

These attributes can also be changed using the

ALTER MONITOR

command.

mapdb-subvol

the MapDB subvolume.

The default is the current session MapDB.

option

ALTER LOCAL parameter-and-value;

ALTER MAPDB [mapdb-subvol] { , option } ;

option is

{ BACKUP 0-to-15

}

{

}

{ HOMETERM [ file-name | NONE ]}
{

}

{ MONITOR process-name

}

{

}

{ PRIMARY 0-to-15

}

{

}

{ PRIORITY 1-to-199

}