Syntax, Operands – HP XP7 Storage User Manual
Page 116
Operands of the group subcommand
Monitoring Data
PhyProc Long
Usage statistics about MPs and data recovery and reconstruction
processors
PhyCMPK Long
Usage statistics about access paths and write pending rate
If you run the Export Tool without specifying the long-range subcommand, the data stored in
the whole monitoring term will be exported.
The login subcommand must execute before the long-range subcommand executes.
Syntax
long-range
[[yyyyMMddhhmm][{+|-}ddhhmm]:[yyyyMMddhhmm][{+|-}ddhhmm]]
Operands
The value on the left of the colon (:) specifies the starting time of the period. The value on the right
of the colon specifies the ending time of the period. Specify the term within "Long Range From
XXX To XXX" which is output by the show subcommand.
If no value is specified on the left of the colon, the starting time for collecting monitoring data is
assumed. If no value is specified on the right of the colon, the ending time for collecting monitoring
data is assumed. The starting and ending times for collecting monitoring data are displayed in the
Monitoring Term area in the Monitor Performance window.
Figure 12 Starting and Ending Time for Collecting Monitoring Data
Description
Operand
yyyyMMdd
indicates the year, the month, and the day. hhmm indicates the hour and the
minute.
yyyyMMddhhmm
If yyyyMMddhhmm is omitted on the left of the colon, the starting time for collecting monitoring
data is assumed. If yyyyMMddhhmm is omitted on the right of the colon, the ending time for
collecting monitoring data is assumed.
Adds time (ddhhmm) to yyyyMMddhhmm if yyyyMMddhhmm is specified. For example,
201301120000+010130 indicates Jan. 13, 2013. 01:30.
+ddhhmm
Adds time to the starting time for collecting monitoring data, if yyyyMMddhhmm is omitted.
Subtracts time (ddhhmm) from yyyyMMddhhmm if yyyyMMddhhmm is specified. For example,
201301120000-010130
indicates Jan. 10, 2013. 22:30.
-ddhhmm
Subtracts time from the ending time for collecting monitoring data, if yyyyMMddhhmm is
omitted.
Ensure that mm is 00, 15, 30, or 45. If you do not specify mm in this way, the value on the
left of the colon (:) will be rounded down to one of the four values. Also, the value on the
right of the colon will be rounded up to one of the four values. For example, if you specify
201301010013:201301010048
, the specified value is regarded as
201301010000:201301010100
.
116