Table 38 Error Code and Error Contents When Operating RAID Manager (continued)
Error Content
Error Code
(SSB2)
Error Code
(SSB1)
In Pairresync, all difference setting was abnormally terminated.
CB21
(When connected to XP1024/XP128 Disk Array series) the port number and the
LUN exceed the range that can be set by the series.
CB5C
(When connected to XP1024/XP128 Disk Array series) the LUN and the device
number exceed the range that can be set by the series.
CB5D
When connected to the old model, LUSE pairs with different amounts of capacity
cannot be created.
CB5E
If the path is set between CUs, LUSE pairs with different CUs cannot be created.
CB5F
XP Continuous Access is not installed in the RCU.
CB60
One DKC cannot include both the pair using Escon and the pair using Fibre.
CB62
Paircreate cannot be executed because the P-VOL is the volume for an external
storage system.
CB6E
Paircreate cannot be executed because the S-VOL is the volume for an external
storage system
CB6F
Paircreate cannot be executed because the P-VOL is the migration volume for an
external storage system.
CB71
Paircreate cannot be executed because the S-VOL is the migration volume for an
external storage system.
CB73
The device is not recognized correctly.
CB75
Paircreate cannot be executed because the paths are specified per storage system.
CB76
The used capacity for Data Retention Utility program product on the RCU exceeds
the licence capacity.
CB77
Paircreate cannot be executed because the specified S-VOL is defined as the
command device.
CB78
A request for Paircreate was received. However, the command was rejected because
the specified S-VOL belongs to the different CLPR from the CLPR for the consistency
group that is already registered.
CB7E
Paircreate cannot be executed because the LUN for P-VOL is the LUSE which is
created across the multiple CLPRs.
CBD0
Paircreate cannot be executed because the LUN for S-VOL is the LUSE which is
created across the multiple CLPRs.
CBD1
A copy pair cannot be created because the specified P-VOL is not the P-VOL for XP
Continuous Access Journal.
CBD8
Paircreate cannot be executed because the used capacity for Data Retention Utility
program product on the RCU exceeds the licence capacity.
CBDA
A request for XP Continuous Access Paircreate was received in the XP Continuous
Access-XP Continuous Access Journal combination status. However, the command
was rejected because the Mirror ID for XP Continuous Access Journal was 0.
CBDC
In configuring the XP Continuous Access-XP Continuous Access Journal multi-target,
a request for an XP Continuous Access Paircreate was received. However, the
command was rejected because the XP Continuous Access Journal pair was in
process of copying.
CBDD
Paircreate cannot be executed because the P-VOL is used by XP Snapshot.
CBDE
Paircreate cannot be executed because the S-VOL is used by XP Snapshot.
CBDF
168 Troubleshooting