HP StorageWorks XP Remote Web Console Software User Manual
Page 165

Table 38 Error Code and Error Contents When Operating RAID Manager (continued)
Error Content
Error Code
(SSB2)
Error Code
(SSB1)
The P-VOL is in the process of collection access.
C31A
The P-VOL is blocked.
C31B
The P-VOL is blocked and impossible to access.
C31C
The P-VOL is in the process of format.
C31D
The P-VOL is for read only.
C31E
The number of MCU-RCU logical paths is 0 (for example, not specified).
C320
The number of MCU-RCU logical paths is smaller than the number of minimum paths
that are required to be specified.
C321
The DKC type of the MCU does not support XP Continuous Access.
C322
The RCU’s sequence number, SSID, or CU are invalid.
C324
Copy pair cannot be created because the P-VOL is not available for XP Continuous
Access Software.
C327
The track formats of the P-VOL and the S-VOL do not match.
C328
The S-VOL is protected by Data Retention Utility.
C32A
The P-VOL is protected by Data Retention Utility.
C32B
The S-VOL is protected by Data Retention Utility.
C32C
A request for Paircreate was received. However, the command was rejected because
the specified RCU is an unsupported product.
C32E
The number of cylinders of the XP Continuous Access P-VOLs is not same as or
smaller than that of S-VOLs.)
C32F
The XP Continuous Access volume capacity in the P-VOL is not equal to the one in
the S-VOL.
C330
The S-VOL cache is unavailable.
C332
The S-VOL DFW is disable.
C333
The S-VOL is the P-VOL for XP Continuous Access Asychronous.
C335
The S-VOL includes PIN data.
C336
The S-VOL is in the reserve status.
C337
Copy pair cannot be created because of one of the following reasons:
•
The S-VOL is in the intervention-required condition, protected, or unusable status.
•
The S-VOL is the S-VOL or Reserved volume of XP Business Copy, Reserved volume
of XP Auto LUN, or the volume of XP Continuous Access Journal pair.
C338
A request for Paircreate was received. However, the command was rejected because
the specified RCU is a product not supported by XP Continuous Access.
C33A
The corresponding volume cannot be specified as S-VOL because the volume is used
as another pair’s S-VOL.
C33B
A request for Paircreate was received. However, the command was rejected because
the specified S-VOL was not mounted.
C33C
Pair cannot be created because the S-VOL is not implemented or is blocked (DEV
NOT READY status).
C33E
Troubleshooting When Using RAID Manager
165