Error code and error contents – HP StorageWorks XP Remote Web Console Software User Manual
Page 162
Table 38 Error Code and Error Contents When Operating RAID Manager
Error Content
Error Code
(SSB2)
Error Code
(SSB1)
A request for XP Continuous Access Paircreate was received. However, the command
was rejected because the specified P-VOL belongs to the different CLPR from the
CLPR for the consistency group that is already registered.
4A96
B901
B90A
B90B
B912
D004
You cannot execute the following operations to the XP Continuous Access pair in
2DC configuration:
•
Swap Suspend
•
Takeover
B927
XP Continuous Access pair cannot be created because the Mirror ID is invalid.
B928
The command for the XP Continuous Access pair operation was rejected because
the online microcode replacement is in process.
B929
XP Continuous Access pair cannot be created because the specified volume is a
command device.
B92A
Pair cannot be created because XP Continuous Access is not installed.
B934
The S-VOL hide mode is not supported.
B935
The specified volume is P-VOL. The pair cannot be released because the P-VOL is
specified as an S-VOL.
B93B
The specified volume is S-VOL. The pair cannot be released because the S-VOL is
specified as an P-VOL.
B941
The command was rejected because the volume status is SMPL.
B945
The specified LU is not defined. The DKC configuration might have been changed.
Restart RAID Manager.
B952
The pair operation cannot be executed because the pair status is PSUS, PSUE, or
PDUB.
B97B
The command was rejected because the volume status is SMPL.
B97C
Pair cannot be created because the larger number than the number that is able to
be specified for consistency group number is specified.
If this error occurs even if you omit to specify the consistency group number, contact
HP technical support .
B990
The Swap Resync operation, that is to resynchronize the differential data from P-VOL
to S-VOL after S-VOL is swapped for P-VOL, cannot be performed because the S-VOL
is not in PSUS or SSWS status.
B994
XP Continuous Access pair cannot be created because the RCU path setting for
Remote Web Console is invalid.
B998
The LDEV configuration for the DKC might have been changed while starting the
RAID Manager. Restart the RAID Manager.
B9BD
The source of the command device has run out. Set the command device to Off and
to On again from the LUN Manager.
B9C0
A request for Pairresync was received. However, the command was rejected because
the corresponding pair was not in the Suspend status.
C162
A request for Pairsplit-S was received. However, the command was rejected because
the status change of the S-VOL failed.
C184
162