Table 38 Error Code and Error Contents When Operating RAID Manager (continued)
Error Content
Error Code
(SSB2)
Error Code
(SSB1)
•
The capacity of the volume is different from the capacity of the P-VOL.
•
The volume is initialized by XP Business Copy.
The S-VOL status is not PSUS or PSUE.
C3DB
XP Continuous Access Asynchronous program products is not installed in RCU.
CB11
TrueCopy for Mainframe, XP Continuous Access, and XP Continuous Access Journal
cannot be mixed in the consistency group.
CB12
The consistency group for the RCU cannot be deleted because the reversing operation
between P-VOL and S-VOL by Takeover command failed.
CB19
The consistency group for the RCU was abnormally terminated because the reversing
operation between P-VOL and S-VOL by Takeover command failed.
CB1A
No dummy volume can be created in the S-VOL.
CB1D
The RCU does not support XP Continuous Access.
CB1F
In referring to the function bit, the system information reference was abnormally
terminated.
CB20
In Pairresync, all difference setting was abnormally terminated.
CB21
(When connected to XP1024/XP128 Disk Array series) the port number and the
LUN exceed the range that can be set by the series.
CB5C
(When connected to XP1024/XP128 Disk Array series) the LUN and the device
number exceed the range that can be set by the series.
CB5D
When connected to the old model, LUSE pairs with different amounts of capacity
cannot be created.
CB5E
If the path is set between CUs, LUSE pairs with different CUs cannot be created.
CB5F
XP Continuous Access is not installed in the RCU.
CB60
One DKC cannot include both the pair using Escon and the pair using Fibre.
CB62
Paircreate cannot be executed because the P-VOL is the volume for an external
storage system.
CB6E
Paircreate cannot be executed because the S-VOL is the volume for an external
storage system
CB6F
Paircreate cannot be executed because the P-VOL is the migration volume for an
external storage system.
CB71
Paircreate cannot be executed because the S-VOL is the migration volume for an
external storage system.
CB73
The device is not recognized correctly.
CB75
Paircreate cannot be executed because the paths are specified per storage system.
CB76
The used capacity for Data Retention Utility program product on the RCU exceeds
the licence capacity.
CB77
Paircreate cannot be executed because the specified S-VOL is defined as the
command device.
CB78
A request for Paircreate was received. However, the command was rejected because
the specified S-VOL belongs to the different CLPR from the CLPR for the consistency
group that is already registered.
CB7E
164 Troubleshooting