HP StorageWorks XP Remote Web Console Software User Manual
Page 161
Table 38 Error Code and Error Contents When Operating RAID Manager (continued)
Error Content
Error Code
(SSB2)
Error Code
(SSB1)
A request for Paircreate was received. However, the command was rejected because
the capacity that is used by XP Continuous Access in RCU exceeds the license
capacity. Check the license capacity, including the related program products.
C305
A request for Paircreate was received. However, the command was rejected because
the capacity that is used by XP Continuous Access in RCU exceeds the license
capacity. Check the license capacity, as well as the related program products.
C306
The volume in the RCU or another volume that belongs to the same group is changing
to the Simplex or Suspend status. Retry the operation several minutes later.
C30D
The P-VOL is not in the Simplex status.
C312
The P-VOL is not in the Suspend status.
C313
The P-VOL is not in the Simplex status.
C314
The P-VOL includes PIN data.
C315
The P-VOL is in the process of drive copy for failure assistance.
C316
The P-VOL is in the process of drive copy for an SVP request.
C317
The P-VOL is terminating the copy task.
C318
The PVOL is in the process of collection copy.
C319
The P-VOL is in the process of collection access.
C31A
The P-VOL is blocked.
C31B
The P-VOL is blocked and impossible to access.
C31C
The P-VOL is in the process of format.
C31D
The P-VOL is for read only.
C31E
The number of MCU-RCU logical paths is 0 (for example, not specified).
C320
The number of MCU-RCU logical paths is smaller than the number of minimum paths
that are required to be specified.
C321
The DKC type of the MCU does not support XP Continuous Access.
C322
The RCU’s sequence number, SSID, or CU are invalid.
C324
Copy pair cannot be created because the P-VOL is not available for XP Continuous
Access Software.
C327
The track formats of the P-VOL and the S-VOL do not match.
C328
The S-VOL is protected by Data Retention Utility.
C32A
The P-VOL is protected by Data Retention Utility.
C32B
The S-VOL is protected by Data Retention Utility.
C32C
A request for Paircreate was received. However, the command was rejected because
the specified RCU is an unsupported product.
C32E
The number of cylinders of the XP Continuous Access P-VOLs is not same as or
smaller than that of S-VOLs.)
C32F
The XP Continuous Access volume capacity in the P-VOL is not equal to the one in
the S-VOL.
C330
The S-VOL cache is unavailable.
C332
The S-VOL DFW is disable.
C333
Troubleshooting When Using RAID Manager
161