Error code and error contents – HP StorageWorks XP Remote Web Console Software User Manual
Page 158
To identify the error code using the log displayed on the RAID Manager window, follow the
procedure below. For more information, see the HP XP RAID Manager User's Guide.
1.
Find the error code from the logs displayed on the RAID Manager window.
shows an example of a log displayed on the RAID Manager window.
Figure 57 Example of a Log Displayed on RAID Manager Window
Error codes appear on the right of SSB=. The alphanumeric characters of last four digits on
the left of the comma (,) indicates SSB1 (for example, B9E1), and the alphanumeric characters
of last four digits on the right of the comma (,) indicates SSB2 (for example, B901).
2.
See
to find the meaning of the error code.
For details about the error codes that are not described in
, contact HP
technical support (see
“Calling HP Technical Support” (page 166)
).
Table 38 Error Code and Error Contents When Operating RAID Manager
Error Content
Error Code
(SSB2)
Error Code
(SSB1)
A request for XP Continuous Access Paircreate was received. However, the command
was rejected because the specified P-VOL belongs to the different CLPR from the
CLPR for the consistency group that is already registered.
4A96
B901
B90A
B90B
B912
D004
You cannot execute the following operations to the XP Continuous Access pair in
2DC configuration:
B927
•
Swap Suspend
•
Takeover
XP Continuous Access pair cannot be created because the Mirror ID is invalid.
B928
The command for the XP Continuous Access pair operation was rejected because
the online microcode replacement is in process.
B929
XP Continuous Access pair cannot be created because the specified volume is a
command device.
B92A
Pair cannot be created because XP Continuous Access is not installed.
B934
The S-VOL hide mode is not supported.
B935
The specified volume is P-VOL. The pair cannot be released because the P-VOL is
specified as an S-VOL.
B93B
The specified volume is S-VOL. The pair cannot be released because the S-VOL is
specified as an P-VOL.
B941
The command was rejected because the volume status is SMPL.
B945
The specified LU is not defined. The DKC configuration might have been changed.
Restart RAID Manager.
B952
The pair operation cannot be executed because the pair status is PSUS, PSUE, or
PDUB.
B97B
The command was rejected because the volume status is SMPL.
B97C
158
Troubleshooting