HP StorageWorks Enterprise File Services WAN Accelerator User Manual
Page 186
186
C
REATING
HP EFS WAN A
CCELERATOR
R
EPORTS
AND
L
OGS
Memory Paging
Whether the system has reached the memory paging threshold. If
100 pages are swapped approximately every two hours the HP EFS
WAN Accelerator is functioning properly. If thousands of pages are
swapped every few minutes, then reboot the HP EFS WAN
Accelerator. For detailed information, see
. If rebooting does not solve the
problem, contact HP technical support.
Network Bypass
Whether the system is in bypass mode. If the HP EFS WAN
Accelerator is in bypass mode, restart the HP EFS WAN Accelerator
service.
If restarting the service does not resolve the problem, reboot the HP
EFS WAN Accelerator. For detailed information, see
HP EFS WAN Accelerator” on page 145
.
If rebooting does not resolve the problem, shutdown and restart the
HP EFS WAN Accelerator. For detailed information, see
the HP EFS WAN Accelerator” on page 145
Stopping Services” on page 144
.
NFS V2/V4 Alarm
Whether the system has triggered a v2 or v4 NFS alarm.
Optimization
Service
Whether the system has detected a software error in the HP EFS
WAN Accelerator service. The HP EFS WAN Accelerator service
continues to function, but an error message appears in the logs that
you should investigate. For detailed information, see
EFS WAN Accelerator Logs” on page 201
Proxy File Service
Partition Full
Whether you Proxy File Service (PFS) partition is full.
Alarm
Description