Pprc commands with shadowimage and truecopy, Psf and devserv commands, 25 psf command operability for shadowimage volumes – HP XP Business Copy Software User Manual
Page 83: 26 psf and devserv results for shadowimage volumes
ShadowImage for z/OS user guide
83
PPRC Commands with ShadowImage and TrueCopy
Both SI390 and TC390 support PPRC commands. The user must ensure that commands are being executed
by the correct program against the correct volumes. A PPRC command issued to the
XP1024/XP128/XP12000/XP10000/SVS 200 will be executed by SI390 against SI390 pairs if all of the
following conditions are met. If any of these conditions is not met, the PPRC command will be executed by
TC390 against TC390 pairs.
1.
The SI390 feature and software must be installed and enabled on the
XP1024/XP128/XP12000/XP10000/SVS 200.
2.
The serial numbers of the S-VOL and the T-VOL must be defined according to either of the following:
a. Enter the same serial number for both S VOL and T VOL.
b. Enter an additional parameter instead of the serial number for the S VOL, and enter the serial
number for the T VOL.
For details about an additional parameter, see
3.
If the XP1024/XP128/XP12000/XP10000/SVS 200 contains TC390 pairs, at least one SI390 pair
must exist before the command is issued.
a. If the XP1024/XP128/XP12000/XP10000/SVS 200 contains both SI390 and TC390 pairs, PPRC
and PPRCOPY commands that specify the same serial number for the primary (source) and
secondary (target) volumes will be executed by SI390.
b. If the XP1024/XP128/XP12000/XP10000/SVS 200 does not contain any SI390 or TC390 pairs,
PPRC and PPRCOPY commands that specify the same serial number for the primary (source) and
secondary (target) volumes will be executed by SI390.
c. If the XP1024/XP128/XP12000/XP10000/SVS 200 contains TC390 pairs but no SI390 pairs,
PPRC and PPRCOPY commands that specify the same serial number for the primary (source) and
secondary (target) volumes will be executed by TC390.
d. If the XP1024/XP128/XP12000/XP10000/SVS 200 contains a M-VOL and a R-VOL of a TC390
pair but no SI390 pairs, you must add at least one SI390 pair. You need to use XP Remote Web
Console and SI390 to create the first SI390 pair.
PSF and DEVSERV Commands
The perform subsystem function (PSF) commands key the XP1024/XP128/XP12000/XP10000/SVS 200 to
accept commands and requests from the user. The following table describes the operability of PSF
commands on SI390 volumes.
describes the PSF Read Subsystem Data and DEVSERV Sense
Subsystem Status results for SI390 volumes.
Table 25
PSF command operability for ShadowImage volumes
Item
Operability for SI390
Device pair status.
See
.
Percent completion of the copy operation.
Not available for SI390 because the SI390 differential bitmap
format is different from the TC390 differential bitmap format.
S-VOL with 2 or more T-VOLs.
Displays information for the pair having the T-VOL with the lowest
LDEV ID.
Path status.
Active.
Path number.
If the volume does not also belong to a TC390 pair, 1 is displayed
with TC390 info.
Table 26
PSF and DEVSERV results for ShadowImage volumes
Pair Status
PSF Read Subsystem Data
DEVSERV Sense Subsystem Status
S-VOL
T-VOL
S-VOL
T-VOL
Pending
PPRI-PNDG
PSEC-PNDG
PPRI-PNDG
PSEC-PNDG
Duplex
PPRIMARY
PSECONDRY
PPRIMARY
PSECONDRY