Resetting the reserve attribute, 27 reset reserve attribute window (unreserve) – HP XP Business Copy Software User Manual
Page 57
ShadowImage for z/OS user guide
57
Resetting the Reserve Attribute
Use the Reset Reserve Attribute window to reset the reserve attribute for (that is, unreserve) the volume(s)
selected on the ShadowImage main window. To open the Reset Reserve Attribute window, select one or
more reserved simplex volumes in the Volume List box on the ShadowImage main window, right-click to
display the pop-up menu, and then click Change Reserve.
Figure 27
Reset Reserve Attribute window (unreserve)
The Reset Reserve Attribute window displays the reserved volume(s) that you selected on the ShadowImage
main window. The OK button resets the reserve attribute for reserved volume(s).
NOTE:
The Preset Volume List box on the ShadowImage main window displays the setting(s). The Cancel
button closes the Reset Reserve Attribute window without changing the settings. To apply the settings to the
XP1024/XP128/XP12000/XP10000/SVS 200, click Apply on the ShadowImage main window.
To unreserve one or more volumes (reset the reserve attribute):
1.
Verify that the volumes you want to unreserve are no longer assigned to SI390 pairs as T-VOLs. For
instructions on deleting SI390 pairs, see ”
2.
From the ShadowImage main window, click the CU image or LDEV in the Tree View box.
3.
Display reserved simplex volumes in the Volume List box. For example, to display reserved simplex
volumes, select the Reserved check box in the Display Filter window.
4.
Select the volume(s), right-click to display the pop-up menu, and then click Change Reserve. The Reset
Reserve Attribute window is displayed. If the Change Reserve command is not enabled, you selected
paired volumes. Select only reserved and unpaired volumes.
5.
From the Reset Reserve Attribute window, click the volume(s) you want to unreserve and then click OK.
The setting will be reflected in the Preset Volume List box on the ShadowImage main window.
6.
From the ShadowImage main window, click Apply.
7.
Verify that the settings are reflected in the XP1024/XP128/XP12000/XP10000/SVS 200. Check the
attribute by clicking Display Filter.