HP XP P9000 for Compatible High Perf FICON Connectivity Software User Manual
Page 58
2.
Click
to change to Modify mode.
3.
In the Performance Control window, click Performance Control. The Performance Control main
window appears.
4.
Ensure that the WWN tab is visible.
The two trees are displayed in the left side of the WWN tab. The upper-left tree lists ports in
the storage system.
5.
Select All from the list at the top right corner of the window.
6.
In the upper-left tree, double-click a port.
7.
Double-click Non-Monitor below the specified port.
If there are any host bus adapters whose traffics with the specified port are not monitored,
those host bus adapters are displayed below Non-Monitor.
8.
Right-click Monitor and then select Add WWN.
The Add WWN window opens where you can add a WWN of a host bus adapter to Monitor.
9.
In the Add WWN window, specify the WWN and the PFC name.
Expand the WWN list to show the WWNs of the host bus adapters that are connected to the
port but are not monitored. These host bus adapters are the same as that displayed in step 7.
From that list, select a WWN and specify the PFC name (up to 64 characters).
We recommend that you specify the same names for the PFC names and the nicknames of
the host bus adapters for convenience of host bus adapter management. Nicknames are
aliases of host bus adapters defined by LUN Manager. In the Performance Monitor window,
not only PFC names but also nicknames are displayed as the aliases of host bus adapters
(WWNs) in the list. Therefore, if you specify both the same aliases, the management of the
host bus adapters is easier.
10. Click OK. The selected WWN (of the host bus adapter) is moved from Non-Monitor to Monitor.
If the specified host bus adapter is connected to other ports, after clicking OK, a message
appears asking whether to change the settings of that host bus adapter for other ports, too.
Make the same setting for all the ports.
11. Repeat step 8 to 10 to move all the host bus adapters displayed below Non-Monitor to below
Monitor.
If you disconnect a host that has been connected via a cable to your storage system or change
the port to the another port of the host, the WWN for the host will remain in the WWN list
of the WWN tab. If you want to delete the WWN from the WWN list, you can delete the
WWN by using LUN Manager. For detail information of the deleting old WWNs from the
WWN list, see the HP XP P9000 Provisioning for Open Systems User Guide.
12. Click Apply in the Performance Control main window. The settings on the window are applied
to the storage system.
58
Performance Control operations