d) Opens the STRTPE file in block mode Edit so that the user can set the
following basic options:
d.1 PARAM LISTENER-PROCESS <$abcd>
This is a required parameter.
It provides the process manager with the process name with
which to start the TCP Listener.
Example: PARAM LISTENER-PROCESS $ZPE02
d.2 PARAM TCP-PROCESS <$abcd>
This is an optional parameter.
This is passed to the TCP listener by the process manager
and indicates what TCP process to use to communicate with PE
SIM plug-in component. If this is omitted, the default TCP
Process as defined by the TCP standard is used.
Example: PARAM TCP-PROCESS $ZTC0
d.3 PARAM ANALYZER-PROCESS <$abcd>
This is a required parameter.
It provides the CPU metrics collector with the process name
with which to start the CPU metrics analyzer.
Example: PARAM ANALYZER-PROCESS $ZPE03
d.4 CPU, Priority, Name and Home terminal assignment of processes as
necessary.
d.5 Note: If you are not using CLIMs on your NonStop system, you will
need to disable the CLIM collector modules from running by
commenting out the following lines:
RUN PECIP /NAME $ZPE08, NOWAIT, TERM $ZHOME /
RUN PECLIM /NAME $ZPE09, NOWAIT, TERM $ZHOME /