Command Line Interface
Table 4-5: Enclosure Management Commands
continued
Command Description
Restrictions
SET ENCLOSURE
UID [ON |
OFF]
Turns the enclosure Unit Identification
LED on or off
Only enclosure administrators
may execute this command.
SET RACK NAME
Sets the name for the rack where the
enclosure resides
Only enclosure administrators
may execute this command.
The
characters long and includes all
alphanumeric, dash, and
underscore characters.
The default rack name is
“UnnamedRack.”
SHOW BAUDRATE
Shows the baudrate settings for blades
1-20 and switches A, B.
Only enclosure administrators
may execute this command.
SHOW CONFIG
Displays the script required to recreate
the settings of the enclosure
Passwords are not included for any
user.
Only enclosure administrators
may execute this command.
SHOW DATE
Displays the current date, time, and
time zone of the internal clock of the
enclosure.
None
SHOW DISPLAY
EVENT
Displays whether event notification is
on or off.
None
SHOW
ENCLOSURE FAN
[
| ALL]
Displays the status, redundancy,
partner, speed, and part number for
the requested fan.
If ALL is entered, this information is
shown for all fans.
None
SHOW
ENCLOSURE
INFO
Displays the enclosure name, type,
part number, serial number, and asset
tag; the Integrated Administrator
software and hardware version;
Integrated Administrator MAC address;
and the interconnect tray type, part
number, and serial number.
None