HP ProLiant BL10e G2 Server Blade User Manual
Page 112

Command Line Interface
Table 4-8: Functionality Exclusive to the Command Line Interface
continued
Function Description
Capability Exclusive to the
Command Line Interface
Enclosure Management Commands, continued
CLEAR BAY BOOT
[FIRST | ONCE]
[ALL |
- ]
Clears the setting for the IPL to be
passed to the blade at the next
reboot. The “FIRST” argumen t
resets the IPL for all subsequent
reboots. The “ONCE” argum ent
resets the IPL for the next reboot
only. This command is only valid for
present blades.
This command requires BIOS
version 06/15/02 or greater for the
ProLiant BL10e server blade ROM.
Only enclosure and group
administrators may execute this
command.
GENERATE NMI
Generates an NMI on the specified
blade.
The consequences of an NMI are
operating system specific.
All
POWERON BAY
{[ , | - ]
{[PXE | HDD |
RBSU]}
Powers on the specified server
blade.
If no server blade is in the specified
bay, the user is told that the bay is
empty.
The optional book arguments require
a BIOS version of 06/15/02 or
greater of the ProLiant BL10e Server
blade ROM.
Adding an optional boot argument
forces the blade to abandon the
regular boot order and forces a boot
using the specified method.
Allows for optional boot argument
continued
4-34
HP ProLiant BL e-Class Integrated Administrator User Guide
HP CONFIDENTIAL
Writer: Hilary Stead File Name: e-ch4 Command Line Interface.doc
Codename: Halo Part Number: 249070-005 Last Saved On: 3/1/04 10:46 AM