HP ProLiant BL10e G2 Server Blade User Manual
Page 102

Command Line Interface
Table 4-6: Server Bay Management Commands
continued
Command Description Restrictions
SET BAY BOOT ONCE
[HDD | PXE | RBSU]
- ]
Sets the boot device to be
used on the next boot of the
bay(s) specified. This setting is
only valid on present blades
and is cleared if the blade is
removed.
This command requires BIOS
version 06/15/02 or greater for
the ProLiant BL10e server
blade ROM.
Only enclosure and
administrators may execute
this command.
SET BAY UID
OFF]
Turns a Unit Identification LED
on the server blade on or off.
Only enclosure and group
administrators may execute
this command.
SHOW BAY INFO [ALL |
- ]
Displays the following fields:
Assigned to group, type, name,
installed operating system, part
number, serial number, asset
tag, BIOS version, all CPU
types and associated
maximum speeds, memory,
NIC #1 MAC, and NIC #2
MAC.
If no server is in the bay, the
user is shown the assigned to
group and the server blade
type.
Group members and group
administrators only see
information for the bays in their
groups.
SHOW BAY LIST [ALL |
Displays the assigned to
group, remote console user,
and server blade name for
each bay in a particular group
if a group name is specified or
all bays if ALL is specified
Group members and group
administrators only see
information for the bays in their
groups.
continued
4-24
HP ProLiant BL e-Class Integrated Administrator User Guide
HP CONFIDENTIAL
Writer: Hilary Stead File Name: e-ch4 Command Line Interface.doc
Codename: Halo Part Number: 249070-005 Last Saved On: 3/1/04 10:46 AM