Command Line Interface
Enclosure Management Commands
Table 4-5: Enclosure Management Commands
Command Description
Restrictions
CLEAR SYSLOG
ENCLOSURE
Clears the enclosure system log
Only enclosure administrators
may execute this command.
Once deleted, this information
cannot be restored.
POWEROFF
ENCLOSURE
{FORCE}
Performs a graceful shutdown of the
enclosure. Each blade is first gracefully
shutdown. If the FORCE argument is
given, the enclosure and all blades are
immediately shutdown.
Only enclosure administrators
may execute this command.
RESTART
Restarts the Integrated Administrator.
This does not affect current operation
of bays in the system.
Only enclosure administrators
may execute this command.
SET BAUDRATE
SWITCH [ A |
B ] [ 1200 |
2400 | 4800 |
9600 | 19200
| 38400 |
57600 |
115200 ]
Sets the baudrate for the switch A or B
to be used while connecting to the
switch console. The valid baudrate
settings that can be specified are 1200,
2400, 4800, 9600, 19200, 38400,
57600 and 115200. In case no prior
baudrate setting is made for switch A
or B the default baudrate of 115200 will
be used. In all cases the other default
settings used are 8 data bits, 1 stop bit,
no parity.
Only enclosure administrators
may execute this command.
continued
4-16
HP ProLiant BL e-Class Integrated Administrator User Guide
HP CONFIDENTIAL
Writer: Hilary Stead File Name: e-ch4 Command Line Interface.doc
Codename: Halo Part Number: 249070-005 Last Saved On: 3/1/04 10:46 AM