HP ProLiant BL10e G2 Server Blade User Manual
Page 139

Setting Up the System
Example e-mail:
----SAMPLE START----
Subject: HP AlertMail-010: (CRITICAL) Power Supply #1: Failed
Date: Wed, 23 Apr 2003 15:02:22 +0200
From: Enclosure IA-00508BEBA571 <[email protected]>
To: user@userdomain
X-OS: HP Integrated Administrator
X-Priority: 1
Content-Type: text/plain; charset=us-ascii
EVENT (26 May 07:09): Power Supply #1 Status has changed to: Failed
Enclosure, IA-00508BEBA571, has detected that a power supply in bay 1 has
changed from status OK to Failed.
The power supply should be replaced with the appropriate spare part. You can
ensure that the center wall assembly is operating correctly by swapping the two
power supplies. Make sure that there are no bent pins on the power supply
connectors before reinserting and that each power supply is fully seated.
An amber LED on the power supply indicates either an over-voltage, over-
temperature, or loss of AC power has occurred. A blinking LED on the power
supply indicates a current limit condition.
Enclosure Status: Degraded
Enclosure Management URL: <
https://16.181.75.213/>
- PLEASE DO NOT REPLY TO THIS EMAIL –
----SAMPLE END----
5-24
HP ProLiant BL e-Class Integrated Administrator User Guide
HP CONFIDENTIAL
Writer: Hilary Stead File Name: f-ch5 Setting Up the System.doc
Codename: Halo Part Number: 249070-005 Last Saved On: 3/1/04 10:50 AM