Proseries, Sonic-pro, 10 transducer mounting clamps – Blue-White Sonic-Pro Hybrid Ultrasonic Flowmeters User Manual
Page 47
Page 47
Sonic-Pro
Industries, Ltd.
Industries, Ltd.
ProSeries
by Blue-White Ind.
TM
6.10
Transducer
Mounting
Clamps
The meter is provided with five pipe clamps, four to be used for transducer mounting and
a fifth for mounting the SPU.
The clamps can be chained together if required for larger pipe diameters.
Additional clamps can be purchased from the factory.
Carefully place the first transducer onto the pipe
. Be sure the
transducer is placed straight and parallel to the pipe centerline.
Secure the first transducer to the pipe using the enclosed pipe clamps. The arrows on the
front and rear of the transducers must point toward the pipe centerline mark.
Locate the second transducer separation mark (B).
Be sure
that both transducers are facing each other and parallel to the pipe centerline.
Check that the separation distance is correct. Tighten the clamps equally.
A single clamp can be used on a pipe diameter of up to 10
inches.
so that the front arrow on the
transducer is located exactly over the first separation distance mark (A)
Carefully place the second transducer
onto the pipe so that the front arrow on the transducer is located exactly over the mark
(B). Be sure the transducer is placed straight and parallel to the pipe centerline.
A
B
Separation
Distance
A
B
BLUE
GASKET
MOUNTING CLAMPS
A
B
CENTERLINE
CENTERLINE
FRONT VIEW
ARROW ON CENTERLINE
REAR VIEW
ARROW ON CENTERLINE
CENTERLINE
CENTERLINE