Proseries, Sonic-pro, 4 transducer separation distance – Blue-White Sonic-Pro Hybrid Ultrasonic Flowmeters User Manual
Page 41
NO
NO
Air bubble
Sediment
NO
NO
Down flows
must have
back pressure
Pipe must be full
Air could be trapped
!
Page 41
Sonic-Pro
Industries, Ltd.
Industries, Ltd.
ProSeries
by Blue-White Ind.
TM
When the meter is operated in the Doppler measurement method, the transducers are
ALWAYS mounted directly opposite each other. The separation is therefore zero.
When the meter is operated in the Transit-Time measurement method, the front faces
of the transducers must be positioned the correct distance apart.
The separation distance is calculated by the meter using the following variables: pipe
size, pipe type, fluid type and mounting mode (V, Z, etc). When factory configured, the
separation distance and mounting mode is printed on the serial label. If the meter has
not been factory configured, or if a new configuration is required, the
configuration data must be input before proceeding. See
section 5 for instructions on how to create or modify a configuration.
Note that if the actual pipe dimensions or fluid type
from the values
configured, the calculated separation distance will be incorrect.
For meters so equipped, the separation distance (as calculated based on the currently
active configuration set) is also shown on the LCD display and on the Remote
Communications PC Software display screen.
pipe size, pipe type,
fluid type and mounting mode
values are different
6.4
Transducer
Separation
Distance
Separation
Distance
625.38
4345625.38
SETUP
SWAP
RELAY
CLEAR
U.S. Gallons
Relay #2
Relay #1
off
Active
5 T 2.32 in.
[¢¢¢£]
U.S. Gallons / min
Currently Active Configuration set
Separation Distance
Currently Active Configuration set
Separation Distance
LCD Display Screen
Communications PC Software Screen
A
B
1480