NO

NO

Air bubbles may be present

Sediment may be present

Page 43

Sonic-Pro

Industries, Ltd.

Industries, Ltd.

ProSeries

by Blue-White Ind.

TM

Mark First Transducer Location (A)

Mark Second Transducer Location (B)

Measure Separation Distance

TRANSIT TIME V-MOUNT MODE

Centerline

Transit Time V mounting method:

When the meter is operated in the Transit Time method, marking the second transducer
location is required.

The V Mount mode requires careful separation distance measurements. Inaccurate
placement of the transducers may result in insufficient signal strength and poor
measurement accuracy.

Draw a straight centerline, parallel to the center line of the pipe, from the first
transducer location mark (A) through to the second transducer location (B). Place a mark
on the centerline at the correct transducer separation distance.

If the fluid contains little or no particles (up to 10% maximum), operate the meter using
the Transit Time method to obtain the best accuracy.

V-MOUNT MODE

6.7
Transit Time
Transducer
Installation
V Mount Mode