Proseries, Sonic-pro, 3 metering setup (continued) – Blue-White Sonic-Pro Hybrid Ultrasonic Flowmeters User Manual
Page 36
Page 36
Sonic-Pro
Industries, Ltd.
Industries, Ltd.
ProSeries
by Blue-White Ind.
TM
5.4.3
Metering
Setup
(continued)
ENTER
Ç
ESC
È
Configuration Set #3
ÊData Logging
Metering Setup
Log Interval
К
З
180
К
Signal Output --> Analog Output allows you
to specify the mapping of flow rate to the
current value at the 4 to 20 mA analog
output signal. The mapping is specified by
two points on a straight line.
Signal Output --> Pulse Output allows you
to specify the mapping of flow rate to the
frequency of pulses at the digital output
signal. The mapping is specified by two
points on a straight line.
Data Logging --> Log Interval allows you to
specify a regular periodic interval in
seconds, at which flow rate and flow total
will be recorded in a log entry. The factory
default setting is 180 seconds. (see section
7.6 below for more on data logging).
Data Logging --> Log Rate Setpoint allows
you to specify upper and lower flow rates
which, when crossed, will result in log
entries being generated.
Data Logging --> Log Total Setpoint allows
you to specify five total flow values at which
log entries will be generated.
SOS Alarm --> Percent Error Window
allows you to define the percentage of fluid
sound speed change that is acceptable before
an error alarm is triggered. The default
value is 10%. See the index at the back of
this manual for fluid sound speed data.
ENTER
Ç
ESC
È
Configuration Set #3
Ê
Metering Setup
Analog Output
Pulse Output
Signal Output
Ê
ENTER
Ç
ESC
È
Configuration Set #3
ÊSOS Alarm
Metering Setup
Percent Error Window
К
10
К
К
ENTER
Ç
ESC
È
Configuration Set #3
ÊSOS Alarm
Metering Setup
Percent Error Window
К