KROHNE BM 102 Handbook User Manual
Page 63
BM
102
63
5
Technical data
5.1 Technical
data
Application
Range of applications
Continuous level measurement of liquids, pastes, slurries and
powders
Function and system design
Measuring principle
Time domain reflectometry
Equipment architecture
See section 5.2
Input
Measured variable
Distance (between the reference point – gauge flange facing –
and the product surface), level, liquid interface & volume
Measurement range
Variable according to probe type, see Equipment architecture,
section 5.2.1
Blocking Distance
(dead zone)
Variable according to probe type, see probe measurement limits,
see section 5.2.2
Output
Analogue
4 … 20 mA, passive output
Load
Passive outputs
750 ohms maximum
Error signal
22 mA
Temperature drift
25 ppm / K
Resolution
± 3 µA
Digital
HART®, passive output
Digital, Ex ia
HART®, passive intrinsically-safe output
Signal on alarm
Status markers via PC STAR 2 or HART® controller (HHC)
Performance characteristics
Accuracy
Level measurement
Liquids when probe length, L ≤ 15 m or 50 ft.
± 15 mm or 0.6 “ outside the dead zone
Optional: ± 5 mm or 0.2 “
Liquids when probe length, L > 15 m or 50 ft.
± 0.1% of the measured distance
Optional: ± 0.05% of the measured distance
Solids
(powders)
± 20 mm or 0.8 “
with 4 … 20 mA current output
± 0.01% of the measured distance
Reference operating conditions
Ambient temperature
+20°C ± 5°C or +68°F ± 9°F
Ambient air pressure
1013 mbar abs. ± 20 mbar or 14.69 psig ± 0.29 psi
Relative air humidity
60% ± 15%
Reference target
- coaxial probe :
water surface
- single probe :
Ø 0.8 m or Ø 31.5 in. metal plate
- twin probe :
metal block “short circuit”
Free space diameter
> 300 mm * or 11.81” *
Distance to obstruction
> 1 m or > 3.28 ft.
* not necessary for coaxial probe.