beautypg.com

KROHNE BM 70 A_P EN User Manual

Page 21

background image

Installation and operating instructions BM 70 A/P

Page: 21

11/00

B) Wave-Stick

Note the requirements pertaining to diameter and length of the tank fitting:

min. 50 mm/2"

max. X

Tank nozzle

L

6.1.4 Mounting on stilling wells

Antenna Type

Outside

diameter

1

80 mm (3.15”)

1s

76 mm (2.99”)

2, 2s

100 mm (3.94”)

3

140 mm (5.51”)

3s

152 mm (5.98”)

4, 4s

200 mm (7.87”)

If necessary, turn antenna
to size!

Antenna size must match inside
diameter

A standard Wave-Stick will not
function in a stilling well! For
stilling wells 40-55 mm a type
Wave-Stick SW can be used.

Further requirements concerning stilling wells:

The well must be electrically conductive.

Minimum inside diameter of well: 40 mm (1.57"). (BM 70 P: 80 mm,

better > 100 mm).

If possible, use only smooth walled, straight stilling wells. If nevertheless an assembled stilling well

is necessary, abrupt changes in diameter along the pipe should be less than 1 mm (0.04"). Surface
roughness of the inside of the pipe should not be more than + 0.1 mm (0.004").

For the BM 70 P the antenna types 1s, 2s, 3s or 4s have to be used to achieve a high measuring

accuracy.

Version

Length L

max.

height of

fitting X

Standard

384 mm

(15.12”)

150 mm

(15.12”)

Option

500...1000 mm

(19.7” - 39.4”)

L - 234 mm

(L - 9.2”)

60mm