Installation and operating instructions BM 70 A/P

Page: 19

11/00

B) Stilling well or Wave-Guide

A stilling well or Wave-Guide may be mounted in any position on the tank.
(For design layout: see also Section 6.1.4; for block distance: see Section 3.3).

Stilling well application

In a side vessel

BM 70 A Wave-Guide

6.1.3 Mounting on tank fitting

A) Horn antenna

Should be mounted on the tank fitting as close to the horizontal as possible (deviation < ± 2°).

Exception: if product surface is not horizontal, (e.g. particulate materials) the flange can be aligned
roughly parallel to it.

The antenna should project out of the fitting:

Tank nozzle

D

L

A stilling well or Wave-Guide
is positively recommended for
horizontal cylindrical tanks
(to avoid multiple reflections):

Antenna

Diameter D

Length l*

Type 4

200 mm (8”)

335 mm (13.2”)

Type 3

140 mm (5.5”)

223 mm (8.8”)

*

Hastelloy: + 30 mm (1.2”)