beautypg.com

3 repeatability, 4 measured value resolution/hysteresis – KROHNE BM 70 A_P EN User Manual

Page 15

background image

Installation and operating instructions BM 70 A/P

Page: 15

11/00

BM 70 A Precision (with special calibration and certificate):
Only with antenna type 4 (200 mm / 7.87") or stilling well 80 - 200 mm dia. (3 - 8")

-12

-10

-8

-6

-4

-2

0

2

4

6

8

10

12

0

5

10

15

20

25

30

35

40 m

1

± 0.1 %

± 5 mm (0.2")

Distance to flange

block

distance

16

33

49

66

82

98

115

3

131ft

Accuracy

-4

-3.2

-2.4

-1.6

-0.8

0

0.8

1.6

2.4

3.2

4

inch cm

4.8

-4.8

= calibration range

= not verified by calibration

BM 70 P
Only with antenna type 4 (200 mm / 7.87") or stilling well 100 - 200 mm dia. (4 - 8")

-12

-10

-8

-6

-4

-2

0

2

4

6

8

10

12

0

5

10

15

20

25

30

35

40 m

Distance to flange

Accuracy

1

Block-

distance

± 0.01 %

± 1 mm (0.04")

±

20

mm

30

...

16

33

49

66

82

98

115

3

131ft

-0.4

-0.32

-0.24

-0.16

-0.08

0

0.08

0.16

0.24

0.32

0.4

inch mm

0.48

-0.48

5.3 Repeatability

Repeatability is equal to half the value for the error of measurement.

5.4 Measured value resolution/hysteresis

Measured value resolution is: 1 mm / 0.04" for BM 70 A, and 0.1 mm / 0.004" for BM 70 P

Hysteresis is at least 20 times less than the error of measurement.