Technical data – KROHNE BM 26 BASIC_ADVANCED EN User Manual
Page 67
TECHNICAL DATA
8
67
BM 26 BASIC/ADVANCED
www.krohne.com
10/2012 - 4000347004 - HB BM26 Basic/Adv R04 en
Dimensions in mm
Dimensions in inches
Weights in kg and lb
Liquid density
[kg/l]
Dimensions [mm]
a b C-C
ML
c
d
e
g
k
L
p
q
r
s
Øt
Lateral /
Lateral
process
connections
0.58…0.7
1
2 3
4
300…
5300
5
55.5
6
106
15
74
7
32 113
259
70 42.4
0.7…0.99
1
8 3
4
5
55.5
6
106
15
74
7
32 113
259
70 42.4
0.99…2.0
1
9 3
4
5
55.5
6
106
15
74
7
32 113
259
70 42.4
1 For more data, refer to "Floats" at the end of this chapter
2 Optional 1/2NPT or 3/8NPT drain + plug: 480 mm. Optional G1/2 or G3/8 drain + plug: 472 mm. Optional drain flange: 580 mm.
3 Optional 3/8NPT vent: 228 mm. Optional 1/2NPT vent: 228 mm. Optional G1/2 vent: 220 mm. Optional welded OPTIWAVE 7300 trans-
mitter: 542 mm. Optional OPTIFLEX 1300 transmitter with 2 mm single cable probe: 454 mm. Optional flange vent: 328 mm. Optional
DN40 flange: 193 mm.
4 This is equal to the dimension C-C
5 EN flange, type B: 135 mm. EN flange, type C: 135 mm. EN flange, type E: 135 mm. Long stud: 130 mm. Male thread connection: 58 mm.
6 If ambient temperature is -40...-20°C: 85.5 mm (with Plexiglas® cover)
7 Depends on the options selected. Contact your local sales office for more data.
8 Optional 1/2NPT or 3/8NPT drain + plug: 299 mm. Optional G1/2 or G3/8 drain + plug: 291 mm. Optional drain flange: 399 mm.
9 Optional 1/2NPT or 3/8NPT drain + plug: 255 mm. Optional G1/2 or G3/8 drain + plug: 247 mm. Optional drain flange: 355 mm.
Liquid density
[lb/ft³]
Dimensions [inches]
a b C-C
ML
c
d
e
g
k
L
p
q
r
s
Øt
Lateral /
Lateral
process
connections
36.2…43.7
1
2 3
4
12…
208
5
2.2
6
4.2
0.6
2.9
7
1.3
4.4 10.2
2.8
1.7
43.7…61.8
1
8 3
4
5
2.2
6
4.2
0.6
2.9
7
1.3
4.4 10.2
2.8
1.7
61.8…124.8
1
9 3
4
5
2.2
6
4.2
0.6
2.9
7
1.3
4.4 10.2
2.8
1.7
1 For more data, refer to "Floats" at the end of this chapter
2 Optional 1/2NPT or 3/8NPT drain + plug: 18.9¨. Optional G1/2 or G3/8 drain + plug: 18.6¨. Optional drain flange: 22.8¨.
3 Optional 3/8NPT vent: 9.0¨. Optional 1/2NPT vent: 9.0¨. Optional G1/2 vent: 8.6¨. Optional welded OPTIWAVE 7300 transmitter: 21.3¨. Op-
tional OPTIFLEX 1300 transmitter with 0.08¨ single cable probe: 17.9¨. Optional flange vent: 12.9¨. Optional DN40 flange: 7.6¨.
4 This is equal to the dimension C-C
5 EN flange, type B: 5.3¨. EN flange, type C: 5.1¨. EN flange, type E: 5.3¨. Long stud: 5.1¨. Male thread connection: 2.3¨.
6 If ambient temperature is -40...-4°F: 3.4¨ (with Plexiglas® cover)
7 Depends on the options selected. Contact your local sales office for more data.
8 Optional 1/2NPT or 3/8NPT drain + plug: 11.8¨. Optional G1/2 or G3/8 drain + plug: 11.4¨. Optional drain flange: 15.7¨.
9 Optional 1/2NPT or 3/8NPT drain + plug: 10¨. Optional G1/2 or G3/8 drain + plug: 9.7¨. Optional drain flange: 14.0¨.
Weights
Weights for every
additional 100 mm
Weights for every
additional 4 inches
[kg]
[lb]
[kg]
[lb]
Min.: DN15 PN40 flanges
7.4…8
1
16.3…17.6
2
0.3
0.7
Max: 1½¨ 600 lb flanges
12.4…13
1
27.3…28.7
2
0.3
0.7
Limit switch
0.085
0.2
1 When L=500 mm - if liquid density is low, then weight is higher
2 When L=20¨ - if liquid density is low, then weight is higher