beautypg.com

Technical data – KROHNE BM 26 BASIC_ADVANCED EN User Manual

Page 67

background image

TECHNICAL DATA

8

67

BM 26 BASIC/ADVANCED

www.krohne.com

10/2012 - 4000347004 - HB BM26 Basic/Adv R04 en

Dimensions in mm

Dimensions in inches

Weights in kg and lb

Liquid density

[kg/l]

Dimensions [mm]

a b C-C

ML

c

d

e

g

k

L

p

q

r

s

Øt

Lateral /
Lateral
process
connections

0.58…0.7

1

2 3

4

300…

5300

5

55.5

6

106

15

74

7

32 113

259

70 42.4

0.7…0.99

1

8 3

4

5

55.5

6

106

15

74

7

32 113

259

70 42.4

0.99…2.0

1

9 3

4

5

55.5

6

106

15

74

7

32 113

259

70 42.4

1 For more data, refer to "Floats" at the end of this chapter
2 Optional 1/2NPT or 3/8NPT drain + plug: 480 mm. Optional G1/2 or G3/8 drain + plug: 472 mm. Optional drain flange: 580 mm.
3 Optional 3/8NPT vent: 228 mm. Optional 1/2NPT vent: 228 mm. Optional G1/2 vent: 220 mm. Optional welded OPTIWAVE 7300 trans-

mitter: 542 mm. Optional OPTIFLEX 1300 transmitter with 2 mm single cable probe: 454 mm. Optional flange vent: 328 mm. Optional
DN40 flange: 193 mm.

4 This is equal to the dimension C-C
5 EN flange, type B: 135 mm. EN flange, type C: 135 mm. EN flange, type E: 135 mm. Long stud: 130 mm. Male thread connection: 58 mm.
6 If ambient temperature is -40...-20°C: 85.5 mm (with Plexiglas® cover)
7 Depends on the options selected. Contact your local sales office for more data.
8 Optional 1/2NPT or 3/8NPT drain + plug: 299 mm. Optional G1/2 or G3/8 drain + plug: 291 mm. Optional drain flange: 399 mm.
9 Optional 1/2NPT or 3/8NPT drain + plug: 255 mm. Optional G1/2 or G3/8 drain + plug: 247 mm. Optional drain flange: 355 mm.

Liquid density

[lb/ft³]

Dimensions [inches]

a b C-C

ML

c

d

e

g

k

L

p

q

r

s

Øt

Lateral /
Lateral
process
connections

36.2…43.7

1

2 3

4

12…

208

5

2.2

6

4.2

0.6

2.9

7

1.3

4.4 10.2

2.8

1.7

43.7…61.8

1

8 3

4

5

2.2

6

4.2

0.6

2.9

7

1.3

4.4 10.2

2.8

1.7

61.8…124.8

1

9 3

4

5

2.2

6

4.2

0.6

2.9

7

1.3

4.4 10.2

2.8

1.7

1 For more data, refer to "Floats" at the end of this chapter
2 Optional 1/2NPT or 3/8NPT drain + plug: 18.9¨. Optional G1/2 or G3/8 drain + plug: 18.6¨. Optional drain flange: 22.8¨.
3 Optional 3/8NPT vent: 9.0¨. Optional 1/2NPT vent: 9.0¨. Optional G1/2 vent: 8.6¨. Optional welded OPTIWAVE 7300 transmitter: 21.3¨. Op-

tional OPTIFLEX 1300 transmitter with 0.08¨ single cable probe: 17.9¨. Optional flange vent: 12.9¨. Optional DN40 flange: 7.6¨.

4 This is equal to the dimension C-C
5 EN flange, type B: 5.3¨. EN flange, type C: 5.1¨. EN flange, type E: 5.3¨. Long stud: 5.1¨. Male thread connection: 2.3¨.
6 If ambient temperature is -40...-4°F: 3.4¨ (with Plexiglas® cover)
7 Depends on the options selected. Contact your local sales office for more data.
8 Optional 1/2NPT or 3/8NPT drain + plug: 11.8¨. Optional G1/2 or G3/8 drain + plug: 11.4¨. Optional drain flange: 15.7¨.
9 Optional 1/2NPT or 3/8NPT drain + plug: 10¨. Optional G1/2 or G3/8 drain + plug: 9.7¨. Optional drain flange: 14.0¨.

Weights

Weights for every

additional 100 mm

Weights for every

additional 4 inches

[kg]

[lb]

[kg]

[lb]

Min.: DN15 PN40 flanges

7.4…8

1

16.3…17.6

2

0.3

0.7

Max: 1½¨ 600 lb flanges

12.4…13

1

27.3…28.7

2

0.3

0.7

Limit switch

0.085

0.2

1 When L=500 mm - if liquid density is low, then weight is higher
2 When L=20¨ - if liquid density is low, then weight is higher