8

TECHNICAL DATA

62

BM 26 BASIC/ADVANCED

www.krohne.com

10/2012 - 4000347004 - HB BM26 Basic/Adv R04 en

Note:

• C-C = Centre-to-face length (process connections)
• ML = Measuring length
• L = Overall length
• a = bottom dead zone; b = Distance from the axis of the top connection to the top of the device

Basic version: Top lateral / Bottom axial process connections

Figure 8-4: Top lateral / Bottom axial process connections

1 3/8 NPT threaded connection
2 Optional drain or vent with 3/8 NPT connection (with plug)
3 Welded cap
4 Flange connection
5 Optional long stud (½¨ or ¾¨) connection
6 Optional male thread (½... ¾ NPT or G ½...¾) connection
7 Optional limit switch
8 Level indicator with optional scale
9 Optional support bracket - also refer to "Support bracket option: Dimensions and weight"