TECHNICAL DATA
8
49
BM 26 BASIC/ADVANCED
www.krohne.com
10/2012 - 4000347004 - HB BM26 Basic/Adv R04 en
Process fitting
Standard: Stainless steel (1.4404 / 316L)
-
Option: Hastelloy® C-276 (for the
wetted parts of EN loose flanges
only)
Gaskets
Teflon® tape
4
Standard: Aramid; Teflon® tape
-
Options: Graphite; PTFE
Braid insulation
-
Ceramic fibre (insulation
between the indicator column
and the measuring chamber
when the process temperature is
+100...+300°C / +210...+570°F)
Anti-freeze cover for glass
indicator tube (option)
Plexiglas®
Process connections
Threaded pipes
½
...¾ NPT; G ½...¾
Smooth pipes, 10S
½¨
; ¾¨ in 10S
Flange version
Flange version
Flange version
Flange version
EN
DN15…40 (Form B1) in PN16 / 40 DN15…50 (Form B1, C or E) in
PN16 / 40;
DN15…50 (Form B1, C or E) in
PN63 / 100; others are available
on request
Note: Hastelloy® C-276 flange
connections are only available as
loose flanges with form B1
ASME
½…
1½¨ (RF) in 150 lb / 300 lb
½…
1½¨ (RF) in 150 lb / 300 lb;
others are available on request
Drain and vent connections
Drain options
Drain options
Drain options
Drain options
Thread
Standard: cover with 3/8 NPT
plug
Standard: flange with ½ NPT plug
Option: cover with 1¼ NPT plug
Options: on page 66
Flange
-
Options: all process connection
options
Vent options
Vent options
Vent options
Vent options
Thread
Standard: without (convex cap)
Standard: 3/8 NPT plug
Option: cover with 3/8 NPT plug
Options: flange with ½ NPT plug;
flange with G ½ plug; DN40 top
flange (for radar or TDR level
transmitter) with ½ NPT lateral
vent plug; welded antenna with
½
NPT lateral vent plug; ½ BSPP
screw connection for
OPTIFLEX 1300 C and Ø2 mm
single cable probe, with ½ NPT
lateral vent plug; all process
connection options
Flange
-
Options: all process connection
options
Basic