Operation, 2 analog transmitter (option) – KROHNE BM 26 BASIC_ADVANCED EN User Manual
Page 33
OPERATION
6
33
BM 26 BASIC/ADVANCED
www.krohne.com
10/2012 - 4000347004 - HB BM26 Basic/Adv R04 en
6.1.2 Analog transmitter (option)
General notes
General notes
General notes
General notes
The analog transmitter has transmitter modules for analog and digital outputs. The user can do
the configuration of 4...20 mA + HART®, FOUNDATION™ Fieldbus and PROFIBUS PA® modules.
Use the web links in the table that follows to download the software and device description files.
Configuration data for transmitter modules
For more data about the configuration of the 4...20 mA + HART®, FOUNDATION™ Fieldbus and
PROFIBUS PA® modules, you can download technical documents from the PR electronics
website: www.prelectronics.com (Download Center > Manuals - Data Sheets - Certificates).
The indications on the LCD are in millimetres by default, but inches and % can also be selected.
The configuration of the indicator is given in the procedures that follow:
Transmitter
Manufacturer User configuration
Yes / No?
Software
Device description
files
4...20 mA
INOR
No
-
-
4...20 mA + HART®
PR
Yes
PReset
1
"PRetop 5335" HART DD,
AMS and DTM files
1
FOUNDATION™
Fieldbus
PR
Yes
PReset
1
"5350" DD files
1
PROFIBUS PA®
PR
Yes
PReset
1
"5350" GSD files
1
1 Go to the PR electronics website: www.prelectronics.com (Download Center > Software)
Figure 6-2: Analog transmitter with the optional indicator
1 Non-Ex and Ex i converter housing option
2 4-digit indicator (LCD)
WARNING!
Do not open the housing and configure the indicator in a hazardous area.