TECHNICAL DATA

8

53

BM 26 BASIC/ADVANCED

www.krohne.com

10/2012 - 4000347004 - HB BM26 Basic/Adv R04 en

Electrical connections

Power supply

Power supply

Power supply

Power supply

Voltage

Non-Ex:

Non-Ex:

Non-Ex:

Non-Ex:

12…35 VDC

8…30 VDC

Ex ia, without LCD indicator:

Ex ia, without LCD indicator:

Ex ia, without LCD indicator:

Ex ia, without LCD indicator:

Refer to supplementary instructions or approval certificates

Ex ia, with LCD indicator:

Ex ia, with LCD indicator:

Ex ia, with LCD indicator:

Ex ia, with LCD indicator:

Refer to supplementary

instructions or approval

certificates

-

LCD indicator; voltage drop

2.5 V

2.5 V

Cable entry

M20 × 1.5

Intrinsically-safe circuit data for

Ex ia-approved devices

Refer to supplementary instructions or approval certificates

Input and output

Current output

Current output

Current output

Current output

Output range

4…20 mA

Error signal

Upper value, selectable

21.6 mA

23 mA

Lower value, selectable

3.5 mA

HART

HART

HART

HART®

Description

-

HART® protocol via passive

current output

Multidrop operation

-

Yes, current output = 4 mA

Multidrop address (1...15)

adjustable

Module output

4...20 mA

4...20 mA / HART®

Order code

xF45xBxxxxx

(without LCD indicator)

xF45xExxxxx

(with LCD indicator)

xF45xWxxxxx

(without LCD indicator)

xF45xGxxxxx

(with LCD indicator)