Technical data – KROHNE BM 26 BASIC_ADVANCED EN User Manual
Page 52
8
TECHNICAL DATA
52
BM 26 BASIC/ADVANCED
www.krohne.com
10/2012 - 4000347004 - HB BM26 Basic/Adv R04 en
Measuring accuracy
Accuracy
±
10 mm / 0.4¨ (when density is
constant)
≤ ±0.1% of span
±
10 mm / 0.4¨ (when density is
constant)
≤ ±0.05% of span
Temperature coefficient
≤ ±0.01% of span/°C
≤ ±0.005% of span/°C
EMC immunity influence
< ±0.1% of span
< ±0.1% of span
Operating conditions
Temperature
Temperature
Temperature
Temperature
Operating temperature,
transmitter module
-40…+85°C / -40…+185°F, if there is insulation around the
measuring chamber, specify the temperature in the order. Do not put
insulation around the transmitter housing.
Operating temperature, LCD
indicator
-20…+70°C / -4…+158°F
1
Pressure
Pressure
Pressure
Pressure
Operating pressure
Atmospheric pressure
Other conditions
Other conditions
Other conditions
Other conditions
Warm-up time
5...10 minutes
30 s
Response time
1.5 s
1....60 s
2
Protection category
Transmitter housing without LCD indicator: IP 54
Transmitter housing with LCD indicator: IP 66
Installation conditions
Notes
The analog transmitter is calibrated at the factory and attached to the
measuring chamber before delivery
Dimensions and weight
Refer to the "Technical data: Dimensions and weights" section
Materials
Housing
Polyester-coated aluminium
Reed-chain tube
Stainless steel
Clamp
Stainless steel
Module output
4...20 mA
4...20 mA / HART®
Order code
xF45xBxxxxx
(without LCD indicator)
xF45xExxxxx
(with LCD indicator)
xF45xWxxxxx
(without LCD indicator)
xF45xGxxxxx
(with LCD indicator)