3.4.2 How to attach the bypass level indicator to the tank

Obey the instructions that follow:

• Select bolts and gaskets (not supplied) that agree with the pressure rating of the process

connection and the operating pressure.

• Install the bypass level indicator vertically on the tank.
• Make sure that there is no contamination (dirt etc.) or unwanted objects in the measuring

chamber.

• Make sure that mechanical loadings do not cause damage to the process connections. If

necessary, put supports on the device.

• Install shut-off valves so that the device can be cleaned separately from the tank. Drain the

device only when it is isolated from the tank.

Figure 3-5: How to attach the bypass level indicator to the tank

1 Optional isolation valve
2 Optional vent
3 Optional drain with isolation valve