Operation – KROHNE UFC 400 FOUNDATION FIELDBUS EN User Manual
Page 60
4
OPERATION
60
UFC 400
www.krohne.com
05/2013 - 4002813701 - AD FF UFC 400 R01 en
Value
R/W
Setting:
0: Forward / 1: Reverse
Forward
REV_FLOW2
REV_FLOW2
REV_FLOW2
REV_FLOW2
Reverse Flow 2
Reverse Flow 2
Reverse Flow 2
Reverse Flow 2
R/W
Indicates reverse flow when true.
-
Status
R/W
Setting:
Good Non Cascade / Good Cascade / Uncertain / Bad Not
Connected / Bad / Bad No Comm with Last Useable Value
(LUV)
Bad Not Connected
Value
R/W
Setting:
0: Forward / 1: Reverse
Forward
RTOTAL
RTOTAL
RTOTAL
RTOTAL
Rejected Total
Rejected Total
Rejected Total
Rejected Total
R/W
Indicates the Totalization of BAD or BAD + UNCERTAIN Inputs,
according to INTEG_OPTS.
0.0
SRTOTAL
SRTOTAL
SRTOTAL
SRTOTAL
Snapshot of
Snapshot of
Snapshot of
Snapshot of
Rejected Total
Rejected Total
Rejected Total
Rejected Total
R
The snapshot of RTOTAL, just before a reset.
0.0
SSP
SSP
SSP
SSP
Snapshot of
Snapshot of
Snapshot of
Snapshot of
Setpoint
Setpoint
Setpoint
Setpoint
R
The snapshot of TOTAL_SP.
0.0
STATUS_OPTS
STATUS_OPTS
STATUS_OPTS
STATUS_OPTS
Status Option
Status Option
Status Option
Status Option
R/W
Options which the user may select in the block processing of
status.
Uninitialized
Setting:
Uncertain if Man
STOTAL
STOTAL
STOTAL
STOTAL
Snapshot of Total
Snapshot of Total
Snapshot of Total
Snapshot of Total
R
Indicates the Snapshot of OUT just before a reset.
0.0
TIME_UNIT1
TIME_UNIT1
TIME_UNIT1
TIME_UNIT1
Time Unit 1
Time Unit 1
Time Unit 1
Time Unit 1
R/W
Converts the rate time units in seconds.
Uninitialized
Setting:
1: seconds / 2: minutes / 3: hour / 4: days
TIME_UNIT2
TIME_UNIT2
TIME_UNIT2
TIME_UNIT2
Time Unit 2
Time Unit 2
Time Unit 2
Time Unit 2
R/W
Converts the rate time units in seconds.
Uninitialized
Setting:
1: seconds / 2: minutes / 3: hour / 4: days
TOTAL_SP
TOTAL_SP
TOTAL_SP
TOTAL_SP
Total Setpoint
Total Setpoint
Total Setpoint
Total Setpoint
R/W
The SP for a batch totalization. Not just SP because SP has PV
units and other special properties not used in this application.
0
Setting:
Positive or 0
UNIT_CONV
UNIT_CONV
UNIT_CONV
UNIT_CONV
Unit Conversion
Unit Conversion
Unit Conversion
Unit Conversion
R/W
Factor to convert the engineering units of input 2 into the
engineering units of input 1.
1.0
Setting:
Positive or not 0
UPDATE_EVT
UPDATE_EVT
UPDATE_EVT
UPDATE_EVT
Update Event
Update Event
Update Event
Update Event
R
This alert is generated by any change to the static data.
-
Unacknowledged
R
A discrete enumeration which is set to "Unacknowledged"
when an alarm occurs, and set to "Acknowledged" by a write
from a human interface device or other entity which can
acknowledge that the alarm/event has been noticed.
Uninitialized
Setting:
Uninitialized / Acknowledged / Unacknowledged
Update State
R
A discrete enumeration which gives an indication of whether
the alert is active and whether it has been reported.
Uninitialized
Setting:
Uninitialized / Acknowledged / Unacknowledged
Parameter
Parameter
Parameter
Parameter
DD name
Access
Description and settings
Initial Value